DATASHEET
SkelMod 102V94F-F

- 102V DC nominal voltage
- Ultra-low ESR
- Integrated Supercapacitor Management
- System for effective cell balancing
- Long lifetime - 1 million duty cycles
- CAN bus communication
- 19 inch rack system compatible
| Electrical | Value | Unit |
|---|---|---|
| Product code | 6730139 | |
| Nominal voltage | 102 | V |
| Maximum pulse voltage11 | 108 | V |
| Surge voltage12 | 113 | V |
| Rated capacitance | 94 | F |
| Rated DC 10ms ESR | 5.5 | mOhm |
| Rated DC 1s ESR | 6.3 | mOhm |
| Specific energy3 | 4.7 | Wh/kg |
| Energy density5 | 4.4 | Wh(L |
| Maximum series voltage | 1250* | VDC |
| Rated maximum peak current (for 1 s duration)1,9 | 3.01 | kA |
| Typical short circuit current13 | 23.9 | kA |
| Maximum stored energy2 | 135.8 | Wh |
| Cells in total | 36 | pcs |
| Standards | Value |
|---|---|
| International protection marking (for enclosure) | IEC 60529, IP 20 |
| Isolation protection | IEC 62477-1, OVC2, PD2 |
| EMC immunity | IEC 61000-6-2 |
| EMC emissions | IEC 61000-6-4 |
| Temperature | Value | Unit |
|---|---|---|
| Operating temperature range | ||
| Operating temperature range, Minimum | -20 | °C |
| Operating temperature range, Maximum | +60 | °C |
| Storage temperature range (uncharged) | ||
| Storage temperature range (uncharged), Minimum | -40 | °C |
| Storage temperature range (uncharged), Maximum | +50 | °C |
| Life | Value | Unit |
|---|---|---|
| Lifetime @ 102V and maximum operating temperature | 1500 | Hours |
| Storage life @ temperature −20 – +25°C, uncharged and short-circuited | 5 | Years |
| Projected cycle life @ temperature +20 °C, cycling between VR and VR / 2 | 1,000,000 | Cycles |
| Power | Value | Unit |
|---|---|---|
| Rated nominal power, calculated from 10 ms ESR | ||
| Power6 | 472.9 | kW |
| Specific power, matched Impedance7 | 16.5 | kW/kg |
| Power density, matched Impedance4 | 15.5 | kW/L |
| Rated practical power, calculated from 1 s ESR | ||
| Power6 | 412.9 | kW |
| Specific power, matched Impedance7 | 14.4 | kW/kg |
| Power density, matched Impedance4 | 13.5 | kW/L |
| Supercapacitor management system | Value | Unit |
|---|---|---|
| Nominal auxiliary supply voltage | 24 | V |
| Auxiliary supply voltage range | 16-33 | V |
| Constant current consumption at 24V DC | 0.07** | A |
| Cell balancing method | Controlled resistive balancing | |
| Temperature monitor | 6 NTC sensors | |
| Voltage monitor | Individual Cell | |
| Communication interface | CAN bus 2.0B |
| Physical parameters | Value | Unit |
|---|---|---|
| Mass. Typical | 29 | kg |
| Volume | 30.6 | L |
| Thermal*** | Value | Unit |
|---|---|---|
| Thermal resistance given at ΔT 30 °C (Rth) | 0.065 | °C/W |
| Thermal capacitance (Cth) | 25 | kJ/°C |
| Max continuous current, ΔT = 15°C10 | 191 | A |
| Max continuous current, ΔT = 30°C10 | 270 | A |
| Max continuous current, ΔT = 40°C10 | 312 | A |
| Connectors | ||
|---|---|---|
| Power connector | Ø 13.5 mm Trough hole | |
| Signal connectors | D-sub DE-9 Male D-sub DE-9 Female | |
| Connector location | Front |


Notes
* For maximum series voltage IE32 (EN 60721-3-3) requirements must be followed. For lower temperature contact Skeleton Technologies
** Inrush current for the auxiliary supply: 0.18A
*** Thermal parameters given for cooling airflow rate of 85CFM
(9) The stated maximum peak current should not be exceeded during use. If the limit is to be exceeded by the customer, Skeleton must be consulted beforehand and give approval for the exceeded power load. (10) These values of current refer to begin of life conditions of the
product, for system design 200% ESR should be considered. (11) For occasional momentary use only – do not apply continuously or for continuous cycling!
(12) Absolute maximum voltage – do not use as operating voltage!
(13) For informational purposes – so not use as operating current!
Standard Markings
+ Name of manufacturer, part number, serial number, rated voltage
+ Rated capacitance, negative and positive terminals, warning marking
+ Total energy in watt-hours
Notes
+ All information provided on this data sheet and all subsequent supercapacitors sales and testing are subject to Standard Terms of Service (ToS) available on www.skeletontech.com, document General Terms of Sale for Skeleton Technologies GmbH